AMP 405

AMP 405

4-Channel Mini Installation Power Amplifier 4 × 50 W @ 4 Ohm

Item no.: LDAMP405

Guarantee: 60 months

EAN: 4049521908798

Sliding scale: 1

Unit: Piece

Packaging unit: 6

Series:TICA

Item highlights:

  • Professional mini amplifier
  • 4 × 50 W Class-D amplifier 4 Ohm
  • Small form factor 1/3 19″ rack, 1U
  • Silent operation with passive cooling
  • Connect to third-party control for remote standby
  • External 100–240 V power supply
  • Run in four-channel mode or bridge for two channels @ 100 W in high-power mode
  • Mounting plates for flexible and inconspicuous installation, even above suspended ceilings
  • Auto-standby to save power
  • Four balanced line inputs with parallel input option
  • Four loudspeaker outputs with terminal strips
  • User-friendly front panel with signal, clip, and protection LEDs
  • Optional rack tray for combining with other TICA® series products

Specifications

Product type
Installation power amplifier
Balanced line inputs
4
Powered outputs
4 with output mode selector (Stereo / Parallel / High Power Mode)
Cooling
Convection
Nominal input sensitivity
0 dBu (Volume Max.)
Nominal input clipping
18 dBu (Volume 9 o´clock)
Input impedance
12 Ohm(s)
CNRR
> 48 dB (0 dBu 1 kHz)
Number of input connectors
4
Input Connector
3-pin terminal block (3.81 mm)
DSP Crossover LPF (switchable for CH1-2)
20 Hz - 125 Hz
DSP Crossover HPF (switchable for CH3-4)
125 Hz - 20 kHz
AD/DA converter resolution
24 bit
AD/DA converter sampling rate
48 kHz
Latency
< 2 ms
Type1
Class D
Output modes
Stereo, parallel, high power mode (ST / PAR / HPM)
Amplifier Outputs
4 channels (ST, PAR) / 2 channels (HPM), 2.1 with 2 channels (ST, PAR) and 1 channel (HPM)
Number of output connectors
2
Connector
4-pin terminal block. Pitch 5.08mm
RMS Power ( W )
4 x 50 W @ 4 ohm (ST, PAR) / 2 x 100 W @ 2 ohm (Continuous sine wave, 1 kHz, 10 sec)
Power ( Peak ) (W)
2 x 55 W @ 4 ohm (ST, PAR) / 1 x 110 W @ 2 ohm (Continuous sine wave, 1 kHz, 4 ms)
Minimum load impedance
4 ohm (ST, PAR) / 2 ohm (HPM)
Frequency response (-1 dB)
20 Hz - 20 kHz
THD + N
< 0.02 % (-6 dBu, 20 kHz BW)
SNR
> 100 dB (17 dBu, Volume center, 20 kHz BW, A-weighted)
Max. Gain
22 dB
Protection circuits
over-current, DC, Short circuit, thermal overload, Undervoltage
Remote Standby
GPI port for external momentary buttons
Remote Standby connector
2-pin black terminal block, pitch 3,5mm
Power supply type
External SMPS
Operating voltage
100 V AC - 240 V AC, 50 - 60 Hz
Secondary Voltage
24 V DC
Secondary Current
5 A
Secondary connector
2-pin terminal block (5.08 mm)
Fuse
No
Primary Connector
IEC
Safety class
Class 3
Max. power consumption
230 W (sine 1 kHz with 4 x 4 ohm load)
Idle power consumption
8.5 W (no signal input)
Standby power consuption
< 1 W
Operating temperature ( non-condensing )
0°C - 40°
Max. Humidity during operation
85 %
Time to Auto-standby
20 Min.
Standby wake up time
3 seconds
Standby wake up threshold
-33 dBu
Material
Steel, Plastic Front panel
Dimensions (W x H x D) ( height with rubber feet )
142 mm x 53 mm x 222 mm
Weight
1,84 kg
Accessories (included)
External SMPS, Terminal blocks for electrical connections., Mounting plates for surface mount applications

Description

AMP 405

Part of the TICA® series, AMP405 combines compact size, passive cooling, and high efficiency – ideal for a wide range of audio installation applications.

The highly efficient four-channel 50 W Class-D amplifier can drive low-impedance loudspeakers in different zones.

Its tiny 142 × 44 × 222 form factor and included mounting plates allow it to be installed discreetly almost anywhere: behind screens, under tables, or even in air-handling spaces and above plenum ceilings. Alternatively, it fits into a 1/3 19? rack. Use the optional rack tray to slot up to three TICA® series products alongside each other and build a system to your exact requirements, using minimal rack space.

Terminal strip connections on the balanced line input and speaker output make wiring easy.

With remote-control connectivity to put the power amplifier into standby mode at any time, even when it’s hidden. Optional auto-standby saves power when no audio is running.

The perfect solution for professional installers and users looking for a compact, highly efficient, and easy-to-integrate solution.


Downloads

Manuals
CAD & Drawings
Images & Artwork
Catalogues & Publications
Service & Regulation Documents
Display all
Name
Type
Format
File size
LDAMP405 User Manual User Manual.pdf3.15 MB
LD Systems REACh Declaration Adam Hall GmbHREACh Declaration.pdf493.71 KB
LD Systems RoHS Confirmation Adam Hall GmbHRoHS Confirmation.pdf197.63 KB
LDAMP405 2D Drawing 2D Drawing.dxf8.91 MB
LD Systems Catalogue / Brochure Highlight Brochure InstallCatalogue / Brochure.pdf6.51 MB
LD Systems Catalogue / Brochure Adam Hall Group Product Highlights Spring/Summer 2025Catalogue / Brochure.pdf24.23 MB
LD Systems Catalogue / Brochure Highlight Brochure DJ & MusicCatalogue / Brochure.pdf4.4 MB
LD Systems Manufacturer's Declaration LD-SYSTEMSManufacturer's Declaration.pdf66.91 KB
Product ImagesImages & Artwork.zip-